Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
International Journal of Food Science and Technology ; 2023.
Article in English | Web of Science | ID: covidwho-2233801

ABSTRACT

The coronavirus disease-19 (COVID-19) pandemic caused dietary changes. Humans reduced social activities to prevent the spread of COVID-19, which led to increasing demand for machines to help cook. This work studies the effect of different stirrer modes on the texture of celery, asparagus, green peppers, and spinach during the cooking process and the functional loss of components in vegetables by measuring the changes in vitamin C, total polyphenols, and total flavonoids. The results showed that colour changes and loss of nutrients in each vegetable varied under different stirrer modes. Stirring was found to be the best mode for cooking all four vegetables. In addition, there was a positive correlation between the a* value and functional components during the cooking process, which means that the colour difference and nutritional loss of vegetables can be modulated together. This study provides theoretical guidance for developing the stirring unit in a cooking machine.

2.
Sustainability ; 14(19):12837, 2022.
Article in English | ProQuest Central | ID: covidwho-2066469

ABSTRACT

This manuscript proposes an integrated system for treating hospital solid waste (H.S.W.) consisting of an incineration and frictional sterilization system capable of operating during normal and emergency situations. We analyzed the benefits of integrating different hospital solid waste (H.S.W.) treatment systems with the existing stand-alone incineration system, with a particular emphasis on the thermal friction sterilization integration system. The objective was to define the economic advantages and benefits in terms of resources recovery of using the thermal frictional sterilization–incineration integrated system during the hospital’s normal and emergency/pandemic operating conditions. We modeled three modeling scenarios based on normal and emergency operating conditions. The results show that the H.S.W. was composed of 74% general H.S.W. Existing incineration systems would be the most expensive process because the sanitary transportation cost represented approximately 96% of the H.S.W. costs. The hospital would realize 40–61% savings relative to the existing method if the integrated incineration–frictional systems were implemented to treat 50–70% of H.S.W.;the savings were better than in other scenarios. Proposed scenario 3 had a much better resources recovery factor than scenarios 1 and 2. This modeling study showed that a thermal frictional sterilization–incineration system could work well even under emergency conditions if the H.S.W. in-house sorting/transportation/storage process is modified to cater to other H.S.W. treatment/sterilization systems.

3.
The Journal of Gemmology ; 38(3):284-287, 2022.
Article in English | ProQuest Central | ID: covidwho-2040464

ABSTRACT

First he examined the interactions between the lingering effects of the COVID-19 pandemic and current economic and social transformations. In light of the session in his honour, Dr George Harlow (American Museum of Natural History, New York, USA) chronicled the history of his career, in which he built collections, organised exhibitions and performed geological fieldwork around the world while researching jade, ruby, etc. Pamir rubies formed at unusually low pressures (minimum of 1–1.2 kbar) and a temperature of approximately 760°C. Wim Vertriest (Gemological Institute of America [GIA], Bangkok, Thailand) and co-authors reviewed the identification of low-temperature heat treatment of gem corundum (i.e. up to about 1200°C, which starts causing damage to rutile ‘silk’ inclusions). In another presentation, Dr Dutrow and co-authors investigated the origin determination of Cu-bearing tourmaline using statistical analyses of LIBS and electron microprobe data.

4.
Chinese Journal of Virology ; 36(6):1004-1008, 2020.
Article in Chinese | GIM | ID: covidwho-2034524

ABSTRACT

SARS-CoV-Z treated at 56 degrees C for 30 min can be inactivated effectively. However, the effect of heat treatment on subsequent detection of the RNA of SARS-CoV-2 by real-time reverse transcription-quantitative polymerase Chain reaction (RT-qPCR) has not been reported. We filled this knowledge gap in present study. We used five SARS'CoV-Z-positive throat swabs. Each throat swab was divided into four parts and assigned to a group: control;56 degrees C for 30 min;56 degrees C for 45 min;56 degrees C for 60 min. After heat treatment, SARS-CoV-Z RNA was extracted and detected by RT-qPCR (absolute quantitation using a standard curve). We found that SARS- CoV-Z RNA was reduced by ~40% after treatment at 56 degrees C for 30 ' 60 min. There was no significant difference (P > 0.05 for all) in the test results between the treatment groups (56 degrees C for 30 min;56 degrees C for 45 min;56 degrees C for 60 min). Our study suggested that SARS-CoV-Z specimens could be inactivated at 56 degrees C for 30 min, before RNA extraction and RT-qPCR detection, which could protect the safety of personnel and the environment during testing. Heat inactivation had a limited effect upon RT-qPCR detection but it should be used with caution if the specimen result is near the critical value.

5.
NTIS; 2022.
Non-conventional in English | NTIS | ID: grc-754596
6.
Int J Environ Res Public Health ; 19(12)2022 06 11.
Article in English | MEDLINE | ID: covidwho-1896844

ABSTRACT

Filtering facepiece respirators have been widely used in the fields of occupational health and public hygiene, especially during the COVID-19 pandemic. In particular, disposable respirators have been in high demand, and the waste generated from these disposable products poses a problem for the environment. Here, we aimed to test a practical decontamination method to allow for the reuse of KN95 respirators. In this study, three types of KN95 respirators were heated at 80 °C and 90 °C for different durations (15 min, 30 min, 45 min, 1 h, 2 h, 3 h, 4 h, 6 h, 8 h, 10 h, and 24 h). The filtration efficiencies of the tested KN95 respirators before and after heating were measured, and the changes in microstructure were imaged with a scanning electron microscope (SEM). In addition, a neural network model based on the nonlinear autoregressive with external input (NARX) to predict the filtration efficiency of the KN95 respirator was established. The results show that the temperature and time of dry heating affected particle prevention. The higher the temperature and the longer the heating time, the more obvious the decline in the filtration efficiency of the respirators. When the heating temperature reached 100 °C, the respirator may be no longer suitable for reuse. These results show that a dry heat temperature between 70 °C and 90 °C, and a heating time between 30 min and 2 h is assumed to be a suitable and effective decontamination method for respirators.


Subject(s)
COVID-19 , Respiratory Protective Devices , COVID-19/prevention & control , Decontamination/methods , Filtration , Hot Temperature , Humans , Pandemics/prevention & control , Ventilators, Mechanical
7.
Environ Pollut ; 305: 119312, 2022 Jul 15.
Article in English | MEDLINE | ID: covidwho-1796873

ABSTRACT

Reuse of sewage sludge is a general trend and land application is an essential way to reuse sludge. The outbreak of coronavirus disease has raised concerns about human pathogens and their serious threat to public health. The risk of pathogenic bacterial contamination from land application of municipal sludge has not been well assessed. The purpose of this study was to investigate the presence of pathogenic bacteria in municipal sewage sludge and to examine the survival potential of certain multidrug-resistant enteroaggregative Escherichia coli (EAEC) strain isolated from sewage sludge during heat treatment. The sewage sludge produced in the two wastewater treatment plants contained pathogenic bacteria such as pathogenic E. coli, Shigella flexneri, and Citrobacter freundii. The environmental strain of EAEC isolated from the sludge was resistant to eight types of antibiotics. It could also enter the dormant state after 4.5 h of treatment at 55 °C and regrow at 37 °C, while maintaining its antibiotic resistance. Our results indicate that the dormancy of EAEC might be why it is heat-resistant and could not be killed completely during the sludge heat treatment process. Owing to the regrowth of the dormant pathogenic bacteria, it is risky to apply the sludge to land even if the sludge is heat-treated, and there is also a risk of spreading antibiotic resistance.


Subject(s)
Escherichia coli Infections , Escherichia coli , Anti-Bacterial Agents/toxicity , Escherichia coli Infections/epidemiology , Hot Temperature , Humans , Sewage/microbiology
8.
Appl Environ Microbiol ; 87(19): e0031421, 2021 09 10.
Article in English | MEDLINE | ID: covidwho-1319372

ABSTRACT

Decontamination helps limit environmental transmission of infectious agents. It is required for the safe reuse of contaminated medical, laboratory, and personal protective equipment, and for the safe handling of biological samples. Heat treatment is a common decontamination method, notably used for viruses. We show that for liquid specimens (here, solution of SARS-CoV-2 in cell culture medium), the virus inactivation rate under heat treatment at 70°C can vary by almost two orders of magnitude depending on the treatment procedure, from a half-life of 0.86 min (95% credible interval [CI] 0.09, 1.77) in closed vials in a heat block to 37.04 min (95% CI 12.64, 869.82) in uncovered plates in a dry oven. These findings suggest a critical role of evaporation in virus inactivation via dry heat. Placing samples in open or uncovered containers may dramatically reduce the speed and efficacy of heat treatment for virus inactivation. Given these findings, we reviewed the literature on temperature-dependent coronavirus stability and found that specimen container types, along with whether they are closed, covered, or uncovered, are rarely reported in the scientific literature. Heat-treatment procedures must be fully specified when reporting experimental studies to facilitate result interpretation and reproducibility, and must be carefully considered when developing decontamination guidelines. IMPORTANCE Heat is a powerful weapon against most infectious agents. It is widely used for decontamination of medical, laboratory, and personal protective equipment, and for biological samples. There are many methods of heat treatment, and methodological details can affect speed and efficacy of decontamination. We applied four different heat-treatment procedures to liquid specimens containing SARS-CoV-2. Our results show that the container used to store specimens during decontamination can substantially affect inactivation rate; for a given initial level of contamination, decontamination time can vary from a few minutes in closed vials to several hours in uncovered plates. Reviewing the literature, we found that container choices and heat treatment methods are only rarely reported explicitly in methods sections. Our study shows that careful consideration of heat-treatment procedure-in particular the choice of specimen container and whether it is covered-can make results more consistent across studies, improve decontamination practice, and provide insight into the mechanisms of virus inactivation.


Subject(s)
Decontamination/methods , Hot Temperature , Personal Protective Equipment/statistics & numerical data , SARS-CoV-2/physiology , Specimen Handling/methods , Virus Inactivation , Decontamination/instrumentation , Reproducibility of Results , Specimen Handling/instrumentation
9.
Environ Res ; 198: 111309, 2021 07.
Article in English | MEDLINE | ID: covidwho-1225237

ABSTRACT

SARS-CoV-2 virus and other pathogenic microbes are transmitted to the environment through contacting surfaces, which need to be sterilized for the prevention of COVID-19 and related diseases. In this study, a prototype of a cost-effective sterilization box is developed to disinfect small items. The box utilizes ultra violet (UV) radiation with heat. For performance assessment, two studies were performed. First, IgG (glycoprotein, a model protein similar to that of spike glycoprotein of SARS-COV-2) was incubated under UV and heat sterilization. An incubation with UV at 70 °C for 15 min was found to be effective in unfolding and aggregation of the protein. At optimized condition, the hydrodynamic size of the protein increased to ~171 nm from ~5 nm of the native protein. Similarly, the OD280 values also increased from 0.17 to 0.78 indicating the exposure of more aromatic moieties and unfolding of the protein. The unfolding and aggregation of the protein were further confirmed by the intrinsic fluorescence measurement and FTIR studies, showing a 70% increase in the ß-sheets and a 22% decrease in the α-helixes of the protein. The designed box was effective in damaging the protein's native structure indicating the effective inactivation of the SARS-COV-2. Furthermore, the incubation at 70 °C for 15 min inside the chamber resulted in 100% antibacterial efficacy for the clinically relevant E.coli bacteria as well as for bacteria collected from daily use items. It is the first detailed performance study on the efficacy of using UV irradiation and heat together for disinfection from virus and bacteria.


Subject(s)
COVID-19 , Ultraviolet Rays , Hot Temperature , Humans , SARS-CoV-2 , Virus Inactivation
10.
EJIFCC ; 31(4): 362-368, 2020 Nov.
Article in English | MEDLINE | ID: covidwho-995523

ABSTRACT

The RNA extraction is an important checkpoint for the detection of SARS-CoV-2 in swab samples, but it is a major barrier to available and rapid COVID-19 testing. In this study, we validated the extraction-free RT-qPCR method by heat-treatment as an accurate option to nucleic acid purification in Algerian population.

11.
J Proteome Res ; 19(11): 4428-4441, 2020 11 06.
Article in English | MEDLINE | ID: covidwho-974865

ABSTRACT

Quantitative nuclear magnetic resonance (NMR) spectroscopy of blood plasma is widely used to investigate perturbed metabolic processes in human diseases. The reliability of biochemical data derived from these measurements is dependent on the quality of the sample collection and exact preparation and analysis protocols. Here, we describe systematically, the impact of variations in sample collection and preparation on information recovery from quantitative proton (1H) NMR spectroscopy of human blood plasma and serum. The effects of variation of blood collection tube sizes and preservatives, successive freeze-thaw cycles, sample storage at -80 °C, and short-term storage at 4 and 20 °C on the quantitative lipoprotein and metabolite patterns were investigated. Storage of plasma samples at 4 °C for up to 48 h, freezing at -80 °C and blood sample collection tube choice have few and minor effects on quantitative lipoprotein profiles, and even storage at 4 °C for up to 168 h caused little information loss. In contrast, the impact of heat-treatment (56 °C for 30 min), which has been used for inactivation of SARS-CoV-2 and other viruses, that may be required prior to analytical measurements in low level biosecurity facilities induced marked changes in both lipoprotein and low molecular weight metabolite profiles. It was conclusively demonstrated that this heat inactivation procedure degrades lipoproteins and changes metabolic information in complex ways. Plasma from control individuals and SARS-CoV-2 infected patients are differentially altered resulting in the creation of artifactual pseudo-biomarkers and destruction of real biomarkers to the extent that data from heat-treated samples are largely uninterpretable. We also present several simple blood sample handling recommendations for optimal NMR-based biomarker discovery investigations in SARS CoV-2 studies and general clinical biomarker research.


Subject(s)
Blood Chemical Analysis/standards , Blood Specimen Collection/instrumentation , Coronavirus Infections , Lipoproteins/blood , Magnetic Resonance Spectroscopy/methods , Pandemics , Pneumonia, Viral , Artifacts , COVID-19 , Hot Temperature , Humans , Reproducibility of Results
12.
bioRxiv ; 2021 Jul 07.
Article in English | MEDLINE | ID: covidwho-721088

ABSTRACT

Decontamination helps limit environmental transmission of infectious agents. It is required for the safe re-use of contaminated medical, laboratory and personal protective equipment, and for the safe handling of biological samples. Heat treatment is a common decontamination method, notably used for viruses. We show that for liquid specimens (here, solution of SARS-CoV-2 in cell culture medium), virus inactivation rate under heat treatment at 70°C can vary by almost two orders of magnitude depending on the treatment procedure, from a half-life of 0.86 min (95% credible interval: [0.09, 1.77]) in closed vials in a heat block to 37.00 min ([12.65, 869.82]) in uncovered plates in a dry oven. These findings suggest a critical role of evaporation in virus inactivation via dry heat. Placing samples in open or uncovered containers may dramatically reduce the speed and efficacy of heat treatment for virus inactivation. Given these findings, we reviewed the literature temperature-dependent coronavirus stability and found that specimen containers, and whether they are closed, covered, or uncovered, are rarely reported in the scientific literature. Heat-treatment procedures must be fully specified when reporting experimental studies to facilitate result interpretation and reproducibility, and must be carefully considered when developing decontamination guidelines.

13.
J Aerosol Sci ; 150: 105609, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-613071

ABSTRACT

This study aims to evaluate the filtration performance of three commercially available (3M 8210 respirator, Halyard 48207 surgical mask, and 3M 1820 procedure mask) and two alternative face mask and respirator materials (Halyard H600 sterilization wrap and Cummins EX101) after selected decontamination treatments, including isopropanol (IPA) treatments (soaking or spraying), ultraviolet germicidal irradiation (UVGI), and heat treatments (dry heat at 77 °C or steam heat). Both IPA soaking and spraying removed most electrostatic charges on all four electret materials (three commercial and one alternative), causing significant deterioration of filtration efficiency to unacceptable level. The other non-electret alternative material sustained its N95-grade performance after both IPA soaking and spraying treatments, demonstrating the possible application of IPA disinfection for non-electret alternative respirator/mask materials. UVGI preserved the filtration of all three commercially available respirator/mask materials after up to 10 treatments, suggesting it can be a possible decontamination method for hospital and clinic use without compromising respirator/mask performance. The considerations of the practical implementation of this method was discussed. Between the two heat treatment methods tested, dry heat showed better compatibility with electret material by sustaining both filtration efficiency and fit (tested on commercial respirator only), although adding moisture was reported in favor of virus inactivation. Heat treatment is easily accessible method for general publics to implement at home, while it is recommended to maintain the moisture level below saturation. Comparing to size-integrated method, the size-resolved fractional efficiency measurement technique, although more time consuming, proved to be a better method for evaluating respirator/mask filtration performance after decontaminations by providing more sensitive detection of performance degradation and the capability of distinguishing charge loss to other mechanisms causing efficiency deterioration. Detailed descriptions are provided in methodology part to emphasize the cares needed for an appropriate efficiency evaluation. The limited results in this study on worn masks made of alternative sterilization wrap indicated possible performance degradation of electret material caused by normal human wearing activities, suggesting the need of assessing respirator/mask decontamination strategy by testing practically worn-and-decontaminated/reused samples instead of unworn only-decontaminated counterparts.

14.
SELECTION OF CITATIONS
SEARCH DETAIL